Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
Journal of Bone and Joint Surgery - British Volume, Vol 85-B, Issue SUPP_I, 12-13.  
Copyright © 2003 by British Editorial Society of Bone and Joint Surgery
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Metcalfe, A.J.
Right arrow Articles by Saleh, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Metcalfe, A.J.
Right arrow Articles by Saleh, M.

British Orthopaedic Research Society


Southampton – 24–25 September, 2001

President – Professor D Marsh


REDUCING MOTION IN UNSTABLE SAGITTAL PLANE FRACTURES - PRELIMINARY RESULTS

A.J. Metcalfe; L. Yang; and M. Saleh

Clinical Sciences Centre, Northern General Hospital, Sheffield.

Experience has shown that oblique fractures can be slow to heal and this has been attributed to excess shear at the fracture site. We routinely treat fractures with hybrid external fixation. In previous studies, olive wires placed through the fracture site reduced shear and this has improved healing times. When the fracture is oblique in the sagittal plane, anatomical constraints prevent the use of olive wires and a new solution is required.

A sawbone tibia with a distal sagittal plane oblique fracture (70° obliquity) was stabilised with a Sheffield Hybrid Fixator. In a pilot study various methods of fixation were tested and six were chosen for further testing. Since the pull-out strength of threads in the plastic bone was poor, olive wires cut behind the olive were used as a mechanically equivalent model for the push-pull system. Seventy degree steerage pins could not be used so 25° pins were tested instead. Cyclic compressive forces (at 10mm/min) of up to 200N axially and in four off-axis positions were applied using a universal testing machine. Fracture site linear motion in three dimensions was measured using an inter-fragmentary motion device, sampled at 100Hz. A standard frame was tested before and after each adaptation and all six methods were applied sequentially to each model.

The results suggest that: I) Arched wires are effective especially under greater bends, 2) Push-pull wires are effective and provide a minimally disruptive solution, 3) Steerage pins are effective especially at steeper obliquities but this may not always be practical, and 4) Placing a half pin in the distal fragment is beneficial but less effective than the use of 2 transverse half pins acting in a compression system (Hutson technique).

Abstracts prepared by Dr P E Watkins, Hodgkin Building, Guys Campus, King’s College London.