Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
Journal of Bone and Joint Surgery - British Volume, Vol 85-B, Issue SUPP_I, 13-14.  
Copyright © 2003 by British Editorial Society of Bone and Joint Surgery
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burt, N
Right arrow Articles by Gregg, P.J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Burt, N
Right arrow Articles by Gregg, P.J.

British Orthopaedic Research Society


Southampton – 24–25 September, 2001

President – Professor D Marsh


DOES THE CLINICAL ENVIRONMENT INFLUENCE THE PROPERTIES OF BONE CEMENT?

N Burt; S.M Green; D.S Sandher; and P.J. Gregg

Middlesborough General Hospital, Ayresome Green Lane, Middlesborough

Cementation is an important part of arthroplasty operations. Recent publication of results of Charnley total hip replacement found a rate of early aseptic loosening of 2.3% at 5 years following surgery across a NHS region. There are possibly many reasons for early loosening but precise reasons are still not fully understood, however, it is felt that cementation technique is very important. There seems to be a number of factors involved such as cement mixing techniques and conditions, physical properties of the cement, cementation and surgical techniques, bone-cement interface as well as bone- prosthesis interface. The purpose of this study was to evaluate the effectiveness of the clinical environment in producing bone cement of predictable mechanical and physical properties, and how those properties compare with published data. The investigation compared samples of bone cement, taken from material prepared and used in surgery with cement samples prepared under controlled laboratory conditions and in accordance with ISO materials testing standards.

During 2000–01, 10 total hip replacements were selected for study. All operations involved the use of CMW1 (DePuy) radio-opaque cement, which was mixed using the Vacumix system. In this cohort, all femoral cementations were performed using an 80g cement mix. After careful preparation of the femoral canal, the scrub nurse mixed the cement in accordance with the manufacturer’s instructions. The cement was introduced into the femoral canal, via a nozzle, using the cementation gun and a pressurizer. Following introduction of cement into the canal, the nozzle and cement contained within, was broken off the gun distal to the pressurizer. Once cured, the cement samples were removed from the nozzle, sectioned, and mechanically tested. Due to this novel sample preparation procedure, the tested cement was expected to exhibit mechanical and physical properties characteristic of the cement present in the femoral canal. Samples of CMW1 (Vacumixed) of similar mass and aspect ratio were produced within the laboratory, in accordance with the manufacturers mixing instructions. PMMA bone cement is a brittle, glassy polymer that is susceptible to stress raisers, such as pores, which can reduce the load carrying ability, which in vivo is predominantly compressive in nature. Published mechanical properties of PMMA bone cement vary somewhat, reflecting the dependence of properties on flaw distribution. The density, which provides a measure of porosity, hardness and ultimate compressive strength of the cement samples was measured and compared.

The surgical samples were found to be very consistent in compressive strength (121 ± 6 MPa), density (1.20 ± 0.02 gcm–3) and hardness (23.2 ± 1.6 VHN) and closely matched the mechanical properties of the cement mixed in the laboratory.

This study suggests that for the studied cement and mixing regime, the clinical environment is capable of producing a well-controlled cement product that has reproducible and predictable mechanical properties. Further, the novel sample preparation procedure used suggests that the cement within the femoral cavity should demonstrate equally predictable, mechanical and physical properties.