Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
Journal of Bone and Joint Surgery - British Volume, Vol 90-B, Issue SUPP_I, 2.  
Copyright © 2008 by British Editorial Society of Bone and Joint Surgery
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Talbot, N.
Right arrow Articles by Schranz, P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Talbot, N.
Right arrow Articles by Schranz, P.

British Orthopaedic Association


Birmingham, England: 17–19 September 2003

President: Professor Paul Gregg


THE AO UNREAMED FEMORAL NAIL IN THE MANAGEMENT OF SUBTROCHANTERIC FEMORAL FRACTURES

NJ Talbot; A Rosewarne; IT Sharpe; and PJ Schranz

Royal Devon and Exeter Hospital, Barrack Road, Exeter EX2 5DW

To evaluate if adequate restoration of the medial cortical buttress reduces the high reported incidence of mechanical complications when using the AO unreamed femoral nail with spiral blade (UFN-SB) in the management of subtrochanteric femoral fractures. The clinical notes and radiographs of sixty-five patients treated with the UFN-SB between November 1996 and February 1999 were retrospectively reviewed. Twenty-eight of these fractures were subtrochanteric. Mean patient age was seventy-five and thirteen patients had metastatic disease. At the time of review the patients or their doctor were contacted by telephone to establish accurately the associated morbidity and mortality. Follow up information was obtained for every patient. Post-operative radiographs were assessed for accuracy of fracture reduction.

The medial cortical buttress was adequately restored in every case. This required open fracture reduction in eleven patients and cerclage wires augmented the reduction in eight of these cases. Open reduction did not significantly increase time to fracture union or transfusion requirement. Every surviving patient was fully weight bearing within three months. One patient required a second operation for spiral blade migration but there were no implant breakages or other mechanical complications after a mean follow-up of thirty-seven months.

Conclusion: Adequate restoration of the medial cortical buttress allows the UFN-SB to function as a load-sharing device and achieves reliable skeletal stability in these potentially unstable fractures that typically occur in osteoporotic or pathological bone.

The abstracts were prepared by Mr Tim Briggs. (Editoral Secretary 2003/4) Correspondence should be addressed to him at Lane Farm, Chapel Lane, Totternhoe, Dunstable, Bedfordshire LU6 2BZ, United Kingdom






(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved
Registered charity no: 209299     Print ISSN: 0301-620X
Hip, Knee, Trauma, Upper limb, Foot & Ankle, Paediatrics, Oncology, Spine, Arthroplasty, General