Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
Journal of Bone and Joint Surgery - British Volume, Vol 90-B, Issue SUPP_I, 3.  
Copyright © 2008 by British Editorial Society of Bone and Joint Surgery
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, P.
Right arrow Articles by Villar, R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Lee, P.
Right arrow Articles by Villar, R.

British Orthopaedic Association


Birmingham, England: 17–19 September 2003

President: Professor Paul Gregg


THE EFFECT OF BILATERAL METAL-ON-METAL HIP ARTHROPLASTY ON SERUM METAL ION CONCENTRATIONS

PTH Lee; MT Clarke; A Arora; and RN Villar

BUPA Cambridge Lea Hospital and Orthopaedic Research Unit, Cambridge University, The Old Schools, Cambridge CB2 1TN

Elevated serum cobalt and chromium ion levels associated with carcinogenesis and chromosomal damage in animals have raised concerns that metal-on-metal (MOM) total hip replacement (THR) in humans may produce the same effects over time. Considering that the risks may be related to the level of these ions in the body, this study compared the serum cobalt and chromium ion levels in patients with unilateral versus bilateral 28 mm diameter MOM THR.

All patients having THR at our institution were prospectively registered on a computerised database. From our database, we identified 108 patients with Ultima (Johnson and Johnson, Leeds) MOM THR with 28 mm bearing made of cobalt-chromium alloy. After patient review in clinic and before blood results were known, patient matching was performed by date after surgery at blood sampling, activity level and body mass. Using these stringent criteria, 11 unilateral THR could be adequately matched with 11 bilateral THR. Blood serum was taken with full anti-contamination protocols and serum analysed via inductively coupled plasma mass spectrometry.

The serum cobalt ion level after unilateral MOM THR was 4.4 times normal (median 22 nmol/L, range 15 to 37 nmol/L) compared to 8.4 times normal (median 42 nmol/L, range 19 to 221 nmol/L) for bilateral MOM THR (p=0.001). The serum chromium ion level after unilateral MOM THR was 3.8 times normal (median 19 nmol/L, range 2 to 35 nmol/L) compared to 10.4 times normal (median 52 nmol/L, range 19 to 287 nmol/ L) for bilateral MOM THR (p=0.04).

This study has shown that the serum cobalt and chromium ion levels in patients with bilateral MOM THR are significantly higher than those in patients with unilateral MOM THR. With levels of up to 50 times the upper limit of normal, this finding may be of relevance for the potential development of long-term side effects.

The abstracts were prepared by Mr Tim Briggs. (Editoral Secretary 2003/4) Correspondence should be addressed to him at Lane Farm, Chapel Lane, Totternhoe, Dunstable, Bedfordshire LU6 2BZ, United Kingdom






(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved
Registered charity no: 209299     Print ISSN: 0301-620X
Hip, Knee, Trauma, Upper limb, Foot & Ankle, Paediatrics, Oncology, Spine, Arthroplasty, General