Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
Journal of Bone and Joint Surgery - British Volume, Vol 90-B, Issue SUPP_I, 7.  
Copyright © 2008 by British Editorial Society of Bone and Joint Surgery
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chauhan, S.K.
Right arrow Articles by Sikorski, J.M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Chauhan, S.K.
Right arrow Articles by Sikorski, J.M.

British Orthopaedic Association


Birmingham, England: 17–19 September 2003

President: Professor Paul Gregg


THE PERTH CT PROTOCOL FOR TOTAL KNEE ARTHROPLASTY

S.K. Chauhan; G.W. Clark; R.G. Scott; S. Lloyd; and J.M. Sikorski

Royal Perth Hospital, Radiological Clinic, W.Breidahl, Perth WA

Plain radiographs are a poor indication of the overall coronal, sagittal and axial alignment of a total knee arthroplasty (TKA). We describe a new CT method that allows the mechanical axis in both planes to be defined and seven alignment characteristics to be defined.

A GE Light Speed multislice CT scanner performed a high-speed helical scan from the acetabular roof to the talus in 100 patients following TKA. The knees were scanned in a supine position with the legs in a neutral position. The images were reformatted in coronal, sagittal and axial planes and the mechanical and anatomical axes identified. The femoral component (varus/ valgus, flexion/extension, rotation) as well as the tibial – (varus/valgus, posterior slope and rotation) are measured. Coupled femoro-tibial rotational alignment was assessed by superimposition of the femoral and tibial axial images. The accuracy of this technique has been checked by using a mechanical FARO-arm.

The technique has a low intraobserver error rate of 9% (in each case less than 1 degree) and an accuracy of 3mm in a three-dimensional plane, as determined against an independent FARO arm technique. The CT analysis of 100 patients shows normal tibial baseplate rotation to be 8–12 degrees from the tibial tuberosity.

Conclusion: The CT protocol is the first single radiographic investigation that characterizes all the alignment parameters of a TKA. It sets an excellent standard in planning revision knee surgery and provides a valuable tool in assessing alignment of painful knee replacements as well as in outcome measures of TKA.

The abstracts were prepared by Mr Tim Briggs. (Editoral Secretary 2003/4) Correspondence should be addressed to him at Lane Farm, Chapel Lane, Totternhoe, Dunstable, Bedfordshire LU6 2BZ, United Kingdom






(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved
Registered charity no: 209299     Print ISSN: 0301-620X
Hip, Knee, Trauma, Upper limb, Foot & Ankle, Paediatrics, Oncology, Spine, Arthroplasty, General