Logo of The Journal of Bone & Joint Surgery (Br)
Joint Replacement Instrumentation Limited (JRI) Ad
Quick search:        
          Advanced Search
Guest Access | Sign In

Find articles in this issue containing these keywords:

Contents

November 2004, Volume 86-B, Issue SUPP IV

To see an article: click its Full Text or PDF link.
To review many abstracts: check the boxes to the left of the titles you want, and click the Get All Checked Abstract(s) button.
To see one abstract at a time: click its Abstract link.

 

International Society for Technology in Arthroplasty

CEMENTLESS ALUMINA/ALUMINA CERAMIC TOTAL HIP ARTHROPLASTY. A PROSPECTIVE RANDOMIZED STUDY WITH 12 TO 38 MONTH FOLLOW UP.
Mark A. Newman
J Bone Joint Surg Br 2004 86-B: 393.

WEAR OF BIPOLAR HIP PROSTHESESA.
Kusaba, Y. Kuroki, S. Kondo, I. Hirose, Y. Ito, N. Hemmi, Y. Shirasaki, T. Tateishi, and J. Scholz
J Bone Joint Surg Br 2004 86-B: 393.

FRICTION OF RETRIEVED HIP PROSTHESES
A. Kusaba, Y. Kuroki, S. Kondo, I. Hirose, Y. Ito, N. Hemmi, Y. Shirasaki, T. Tateishi, and J. Scholz
J Bone Joint Surg Br 2004 86-B: 393.

OPTIMUM ABDUCTOR MOMENT ARM FOR TOTAL HIP ARTHROPLASTY
I. Asayama, M. Naito, M. Fujisawa, and T. Kambe
J Bone Joint Surg Br 2004 86-B: 393.

ACETABULAR RECONSTRUCTION WITH KERBOULL REINFORCEMENT DEVICE AND HYDROXYAPATITE GRANULES
C. Tanaka, J. Shikata, M. Ikenaga, and M. Takahashi
J Bone Joint Surg Br 2004 86-B: 393-394.

CLINICAL RESULTS OF CEMENTLESS THA PERFORMED WITH SUBTROCHANTERIC SHORTENING FEMORAL OSTEOTOMY
S. Nagoya
J Bone Joint Surg Br 2004 86-B: 394.

CEMENTLESS TOTAL HIP ARTHROPLASTY WITH AN AUTOGRAFT OF THE FEMORAL HEAD FOR MARKED ACETABULAR DYSPLASIA
T. Yamaguchi
J Bone Joint Surg Br 2004 86-B: 394.

FRICTION IN HIP HEMIENDOPROSTHESES – REVIEW OF LITERATURE AND OWN MODEL USING CADAVERIC ACETABULA
L.P. Müller, J. Degreif, D. Mateja, H. Hely, and P.M. Rommens
J Bone Joint Surg Br 2004 86-B: 394.

COMPARISON OF WEAR DEBRIS INDUCED OSTEOLYSIS ALONG A CEMENTED AND CEMENTLESS INTERFACE: AN ANIMAL MODEL IN THE RABBIT
J.A. Bergandi, J. Feinblatt, M.N. Rumi, M.M. Saunders, S.H. Naidu, and V.D. Pellegrini, Jr.
J Bone Joint Surg Br 2004 86-B: 394.

RETROPATELLAR CONTACT CHARACTERISTICS IN TOTAL KNEE ARTHROPLASTY WITH AND WITHOUT PATELLA RESURFACING DEVICES
S. Fuchs
J Bone Joint Surg Br 2004 86-B: 394.

CLINICAL AND FUNCTIONAL RESULTS AFTER CONSTRAINED TOTAL KNEE ARTHROPLASTY
S. Fuchs, M. Volmer, C.O. Tibesku, and D. Rosenbaum
J Bone Joint Surg Br 2004 86-B: 394-395.

INFLUENCE OF ASEPTIC OR SEPTIC HISTORY AND CHOICE OF CONDYLAR OR HINGED REVISION KNEE ARTHROPLASTY ON CLINICAL-RADIOLOGICAL RESULTS AND QUALITY OF LIFE
S. Fuchs, G. Gerdemann, and D. Bettin
J Bone Joint Surg Br 2004 86-B: 395.

IS THERE ANY CORRELATION BETWEEN CLINICAL RESULTS, LIFE QUALITY AND RADIOLOGICAL PARAMETERS FOLLOWING TOTAL KNEE ARTHROPLASTY?
C. Chylarecki, M.G. Floren, and S. Fuchs
J Bone Joint Surg Br 2004 86-B: 395.

CLINICAL AND FUNCTIONAL COMPARISON OF UNICONDYLAR AND BICONDYLAR KNEE ARTHROPLASTY
S. Fuchs, C. O. Tibesku, H. Laaß, and D. Rosenbaum
J Bone Joint Surg Br 2004 86-B: 395.

QUALITY OF LIFE AFTER ASEPTIC HIP REVISION ARTHROPLASTY IN CONSIDERATION OF CLINICAL RADIOLOGIC FINDINGS
C. Chylarecki, S. Brändle, and S. Fuchs
J Bone Joint Surg Br 2004 86-B: 395.

CT EVALUATION OF FEMORAL ROTATIONAL ALIGNMENT POST TKA: COMPARISON OF THE TIBIAL AXIS TO THE TRANSEPICONDYLAR LINE
J. Boldt, P. Keblish, C. Varma, T. Drobny, and U. Munzinger
J Bone Joint Surg Br 2004 86-B: 395.

CEMENTLESS TOTAL HIP ARTHROPLASTY WITH A CLOSE PROXIMAL FIT AND TAPERED SHORT DISTAL STEM (THIRD-GENERATION) PROSTHESIS
The Joint Replacement Center of Korea
J Bone Joint Surg Br 2004 86-B: 395-396.

INCIDENCE OF FAT EMBOLISM FOLLOWING CEMENTED OR CEMENTLESS BILATERAL SIMULTANEOUS- AND UNILATERAL TOTAL HIP ARTHROPLASTY A PROSPECTIVE RANDOMIZED CLINICAL STUDY
Young-Hoo Kim, S-H. Oh, and J-S. Kim
J Bone Joint Surg Br 2004 86-B: 396.

PELVIC RECONSTRUCTION BY SACRAL IMPLANTATION OF AN ACETABULAR COMPONENT
W.G. Ward, Sr.
J Bone Joint Surg Br 2004 86-B: 396.

ARTHROFIBROSIS IN TKA: IS THERE A CORRELATION WITH FEMORAL COMPONENT MAL-ROTATION?
J. Boldt, J. Romero, J. Hodler, M. Zanetti, T. Drobny, and U. Munzinger
J Bone Joint Surg Br 2004 86-B: 396.

IMPINGEMENT OF THE HOFFA’S FATPAD IN AP-GLIDE TKA
J. Boldt, T. Drobny, and U. Munzinger
J Bone Joint Surg Br 2004 86-B: 396.

VALGUS TOTAL KNEE ARTHROPLASTY. RESULTS OF 255 LCS TKA WITH 5 TO 15 YEAR FOLLOW-UP.
P. Keblish, J. Boldt, T. Drobny, and U. Munzinger
J Bone Joint Surg Br 2004 86-B: 397.

BIOLOGICAL FIXATION IN UNCEMENTED MOBILE-BEARING LCS TKA. ANALYSIS OF 567 LCS TKA WITH 2 TO 15 YEAR FOLLOW-UP.
P. Keblish, T. Kashiwagi, and J. Boldt
J Bone Joint Surg Br 2004 86-B: 397.

THE DEVELOPMENT OF A NEW POROUS STRUCTURE; HYDROXYAPATITE-COATED LAMELLAR ETCHED TITANIUM. – A STUDY IN WEIGHT BEARING CONDITION
H. Kusakabe, T. Sakamaki, K. Nihei, Y. Ohyama, S. Yanagimoto, M. Ichimiya, J. Kimura, and Y. Toyama
J Bone Joint Surg Br 2004 86-B: 397.

CRUCIATE RETAINING AUGMENTABLE PROSTHESIS IN REVISION TOTAL KNEE ARTHROPLASTY
R. Nakamura, K. Kitaoka, H. Yamada, K. Hashiba, and K. Tomita
J Bone Joint Surg Br 2004 86-B: 397.

THE ELBOW AXIS BEFORE AND AFTER TOTAL ELBOW REPLACEMENT
M. Stokdijk, J. Nagels, E.H. Garling, and P.M. Rozing
J Bone Joint Surg Br 2004 86-B: 397.

ANALYSIS BY THREE-DIMENSIONAL COMPUTED TOMOGRAPHY IMAGES OF RESECTED FEMUR ACCORDING TO THE THEORY FOR TOTAL KNEE ARTHROPLASTY
K. Urabe, H. Miura, T. Kuwano, R. Nagamine, S. Matsuda, T. Sasaki, S. Kimura, Y. Iwamoto, and M. Itoman
J Bone Joint Surg Br 2004 86-B: 397-398.

BIOLOGY OF ALKALI-AND HEAT-TREATED TITANIUM IMPLANTS
S. Nishiguchi, S. Fujibayashi, H-M. Kim, T. Kokubo, and T. Nakamura
J Bone Joint Surg Br 2004 86-B: 398.

ENDOSCOPICALLY CONTROLLED CEMENT REMOVAL IN HIP REVISION ARTHROPLASTY
MG. Porsch and J. Schmidt
J Bone Joint Surg Br 2004 86-B: 398.

MECHANICAL EFFECT OF THE ARTICULATING MATERIALS TO THE PROXIMAL FEMUR AND THE FEMORAL STEM IN TOTAL HIP ARTHROPLASTY
K.H. Moon, Y.Y. Yeon*, Y.S. Yu**, B.K. Lee**, and J.Y. Lee
J Bone Joint Surg Br 2004 86-B: 398.

THE SPHERICITY OF THE BEARING SURFACE IN TOTAL HIP ARTHROPLASTY
H. Ito, A. Minami, T. Matsuno, H. Tanino, N. Omizu, and T. Yuhta
J Bone Joint Surg Br 2004 86-B: 398.

THE PRIMARY TOTAL KNEE ARTHROPLASTY USING MIDVASTUS SURGICAL APPROACH
SangHoon Ko, DaeKyung Bae, and YoungJun Park
J Bone Joint Surg Br 2004 86-B: 398.

OSTEOLYSIS IN THE CEMENTLESS ANATOMIC MODULAR KNEE (AMK) TOTAL KNEE ARTHROPLASTY
ES Stem and BM Hicks
J Bone Joint Surg Br 2004 86-B: 399.

ANTHROPOMETRY OF THE PROXIMAL TIBIA TO DESIGN TOTAL KNEE PROSTHESIS FOR THE JAPANESE POPULATION
Y. Kadoya, K. Uehara, A. Kobayashi, H. Ohashi, and Y. Yamano
J Bone Joint Surg Br 2004 86-B: 399.

MODULAR NECK IN HIP PROSTHESIS: MID-TERM RESULTS OF A VERSATILE SOLUTION.
C.L. Romanò, A. Pellegrini, D. Romanò, and E. Meani
J Bone Joint Surg Br 2004 86-B: 399.

BION INJECTABLE NEUROMUSCULAR STIMULATORS FOR MUSCLE STRENGTHENING IN KNEE OSTEOARTHRITIS: PRELIMINARY RESULTS.
C.L. Romano, D. Romano, G.E. Loeb, and F.J.R. Richmond
J Bone Joint Surg Br 2004 86-B: 399.

REPEATABILITY AND SENSITIVITY OF A COMPUTER-AIDED NAVIGATION SYSTEM FOR TOTAL KNEE REPLACEMENT SURGERY
V.K. Sarin, W.R. Pratt, and S.D. Stulberg
J Bone Joint Surg Br 2004 86-B: 399.

CLINICAL EXPERIENCE WITH LPS FLEX KNEE
Sam Tarabichi
J Bone Joint Surg Br 2004 86-B: 399-400.

CALCIUM PHOSPHATE PASTE FOR BONE DEFECT IN TOTAL KNEE ARTHROPLASTY.
T. Sato, A. Nakagawa, A. H. Umeda, and H. Terashima
J Bone Joint Surg Br 2004 86-B: 400.

THE DEVELOPMENT OF A NEW POROUS STRUCTURE; HYDROXYAPATITE-COATED LAMELLAR ETCHED TITANIUM. A INTERFACE STUDY.
Y. Oyama, H. Kusakabe, K Nihei, S. Yanagimoto, Y. Toyama, and T. Sakamaki
J Bone Joint Surg Br 2004 86-B: 400.

METALLOSIS AFTER TOTAL KNEE ARTHROPLASTY USING AGC-S TYPE PROSTHESIS
Hiroshi Yamada
J Bone Joint Surg Br 2004 86-B: 400.

TOTAL SHOULDER ARTHROPLASTY – VARIANTS IN SURFACE SHAPE OF THE GLENOID FOSSA
A.P. Monk, E. Berry, R. Soames, and D. Limb
J Bone Joint Surg Br 2004 86-B: 400.

EARLY RESULTS OF PRIMARY BIRMINGHAM HIP RESURFACING USING A HYBRID METAL-ON-METAL COUPLE.
K. de Smet, R.van Durme, E. Jansegers, and R. Verdonk
J Bone Joint Surg Br 2004 86-B: 400.

A COMPARATIVE STUDY OF INHIBITORY EFFECTS ON PERI-IMPLANT OSTEOLYSIS BETWEEN ANTI-TNFA AND BISPHOSPHONATE IN A RAT MODEL
K.J. Kim, M. Iwase, Y. Kobayashi, and T. Itoh
J Bone Joint Surg Br 2004 86-B: 400-401.

KINEMATIC PATTERN IN DEEP KNEE FLEXION AFTER TOTAL KNEE ARTHROPLASTY
H. Miura, H. Higaki, T. Kawano, Y. Nakanishi, S. Matsuda, and Y. Iwamoto
J Bone Joint Surg Br 2004 86-B: 401.

PREDICTION OF TOTAL KNEE POLYETHYLENE WEAR USING WEAR INDEX
H. Miura, H. Higaki, Y. Nakanishi, T. Mawatari, T. Moro-oka, T. Tsutomu, and Y. Iwamoto
J Bone Joint Surg Br 2004 86-B: 401.

FEMORAL ROLLBACK IN A SINGLE DESIGN CRUCIATE-RETAINING KNEE ARTHROPLASTY – MUTTI-CENTER OBSERVATIONS
H. Nozaki, S. Banks, T. Suguro, and T. Furufu
J Bone Joint Surg Br 2004 86-B: 401.

CHAOS OF THE STRESS FIELD AT THE FIXATION SITE OF A JOINT PROSTHESIS
R. Sakai
J Bone Joint Surg Br 2004 86-B: 401.

THE UNIQUE CUSTOMIZED PROSTHESIS (UCP) IS MORE STABLE THAN THE CEMENTED ELITE PLUS FEMORAL STEM. A RANDOMIZED PROSPECTIVE STUDY WITH RADIOSTEREOMETRIC ONE YEAR FOLLOW UP
L Nordsletten, A Aamodt, P Benum, and P Grant
J Bone Joint Surg Br 2004 86-B: 401.

BETTER ALIGNMENT AND CEMENT MANTLE QUALITY WITH NEW MODERN TECHNIQUE FOR INSERTION OF THE CHARNLEY STEM. A COMPARISON BETWEEN OLD AND NEW TECHNIQUE IN HEMIPROSTHESIS FOR PRIMARY FEMORAL NECK FRACTURE
L Nordsletten, P Grant, and O Talsnes
J Bone Joint Surg Br 2004 86-B: 402.

THE USE OF AN ALL POLYETHYLENE TIBIAL COMPONENT AS AN ALTERNATIVE CHOICE IN PRIMARY TOTAL KNEE ARTHROPLASTY
L. Schaper
J Bone Joint Surg Br 2004 86-B: 402.

MANAGEMENT OF SEPTIC TOTAL HIP ARTHROPLASTIES USING ANTIBIOTIC IMPREGNATED CEMENTED SPACERS
D. Pomeroy
J Bone Joint Surg Br 2004 86-B: 402.

LONG TERM RESULTS USING A SINGLE TOTAL KNEE DESIGN WITH THREE DIFFERENT METHODS OF TIBIAL FIXATION
D. Pomeroy
J Bone Joint Surg Br 2004 86-B: 402.

THE EFFECT OF SURFACE COATING ON A SINGLE STEM DESIGN: A 6 TO 10 YEAR STUDY
L. Schaper
J Bone Joint Surg Br 2004 86-B: 402.

METAL ON METAL BEARING WEAR OF FEMORAL HIP ORTHOPAEDIC IMPLANTS PRODUCED IN COBALT CHROMIUM MOLYBDENUM ALLOY
T. Band, J. Metcalf, and H. Jones
J Bone Joint Surg Br 2004 86-B: 402-403.

THE WEAR OF ALUMINA-ON-ALUMINA TOTAL HIP PROSTHESES
S.C. Scholes, S.M. Green, and A. Unsworth
J Bone Joint Surg Br 2004 86-B: 403.

TOTAL KNEE DESIGN TO SUPPORT HIGH FLEXION KNEE FUNCTION
R. D. Crowninshield, A. M. Patmore, L. Tanamal, and D. M. Blakemore
J Bone Joint Surg Br 2004 86-B: 403.

MID-TERMS RESULTS OF NON-CEMENT K.K.S. TOTAL HIP SYSTEM. -EVALUATION OF BIOLOGICAL FIXATION COMPARED AMONG STEMS WITH DIFFERENT SURFACE STRUCTURES-
S. Yanagimoto, T. Sakamaki, M. Ishibashi, T. Honnma, Y. Ohyama, H. Kusakabe, Y. Yabuki, T. Fujita, and D. Itho
J Bone Joint Surg Br 2004 86-B: 403.

CUSTOMIZE DON’T COMPROMISE- THE CORRELATION OF STEM FIT AND JOINT GEOMETRY
G. Aldinger
J Bone Joint Surg Br 2004 86-B: 403.

SURGICAL APPROACH INFLUENCES CEMENTED FEMORAL STEM MIGRATION
S. Glyn-Jones, H.S. Gill, and D.W. Murray
J Bone Joint Surg Br 2004 86-B: 403.

CERAMIC/POLY VS METAL/METAL IN THA: A SIX YEAR’S.FOLLOW UP. CLINICAL AND X-RAY RESULTS.
T. Philippe
J Bone Joint Surg Br 2004 86-B: 403-404.

CHAOS OF THE STRESS FIELD AT THE FIXATION SITE OF A JOINT PROSTHESIS
R. Sakai
J Bone Joint Surg Br 2004 86-B: 404.

EXTENSIVELY CROSS-LINKING OF UHMWPE TO IMPROVE WEAR PERFORMANCE IN TOTAL HIP REPLACEMENT
R.D. Crowninshield, D.F. Swarts, M.P. Laurent, and J.Q. Yao
J Bone Joint Surg Br 2004 86-B: 404.

CARBON NANOTUBE AUGMENTATION OF THE MECHANICAL PROPERTIES OF BONE CEMENT
D. Pienkowski, R. Andrews, M. Goltz, and T. Rantell
J Bone Joint Surg Br 2004 86-B: 404.

TREATMENT OUTCOME OF TWO-STAGE REVISION TOTAL HIP ARTHROPLASTY FOR INFECTED HIP ARTHROPLASTY USING TEMPORARY ANTIBIOTIC-IMPREGNATED CEMENT SPACER
N. Takahira, M. Itoman, K. Higashi, K. Uchiyama, and M. Miyabe
J Bone Joint Surg Br 2004 86-B: 404.

THE EFFECT OF ACTIVITY PATTERNS AND INTENSITY ON POLYETHYLENE WEAR
M. Silva, W.O. Jackson, E.F. Shepherd, M.A. dela Rosa, and T.P. Schmalzried
J Bone Joint Surg Br 2004 86-B: 404-405.

THE EFFECTS OF BONE DEFECTS CREAARETED BY REMOVAL OF DYNAMIC HIP SCREW ON MICROMOTION AND STRESS CONCENTRATION IN CEMENTLESS HIP REPLACEMENT
Y.Y. Won
J Bone Joint Surg Br 2004 86-B: 405.

ARTHROSCOPIC ARTHROPLASTY FOR THE ADVANCED OSTEOARTHRITIS OF THE HIP JOINT
T. Kusakabe
J Bone Joint Surg Br 2004 86-B: 405.

DEVELOPMENT FOR NEXT GENERATION LOW WEAR ARTICULATIONS
R.M. Streicher, J. Fisher, and G. Insley
J Bone Joint Surg Br 2004 86-B: 405.

ALUMINA/ALUMINA ARTICULATION: MIXING MATERIALS
R. M. Streicher
J Bone Joint Surg Br 2004 86-B: 405.

IN VIVO QUANTIATIVE ANALYSIS OF HIGHLY CROSSLINKED POLYETHYLENE PARTICLES IN TOTAL HIP REPLACEMENTS
H. Iwaki, Y. Minoda, A. Kobayashi, Y. Kadoya, H. Ohashi, H. Oonishi, Y. Yamano, and H. Iwaki
J Bone Joint Surg Br 2004 86-B: 405.

A LONG-TERM RESULTS OF BIPOLAR HEMI-ARTHROPLASTY FOR OSTEOARTHRITIS OF THE HIP
Y. Fujita, S. Yanagimoto, and T. Sakamaki
J Bone Joint Surg Br 2004 86-B: 405-406.

FACTORS THAT INFLUENCE THE INITIAL STABILITY OF STEM FIXED WITH IMPACTED MORSELLIZED ALLOGRAFTS IN REVISION THA
H. Ohashi, A. Kobayashi, Y. Kadoya, Y. Yamano, and Y. Tanabe
J Bone Joint Surg Br 2004 86-B: 406.

IMPLANT DESIGN CONSIDERATIONS IN CEMENTLESS STRAIGHT STEMS – THE INFLUENCE OF COMPUTER ASSISTED PLANNING
A. Bauer
J Bone Joint Surg Br 2004 86-B: 406.

A NOVEL METHOD OF MEASURING POLYETHYLENE WEAR IN TOTAL KNEE ARTHROPLASTY ON STANDARD STANDING RADIOGRAPHS
S. Kobayashi, N. Saito, M. Nawata, H. Horiuchi, H. Oota, R. Iorio, and K. Takaoka
J Bone Joint Surg Br 2004 86-B: 406.

CAN MODULAR NECKS RESTORE HIP GEOMETRY AFTER TOTAL HIP ARTHROPLASTY ?
J.N. Argenson, M. Kacem-Boudhar, and J.M. Aubaniac
J Bone Joint Surg Br 2004 86-B: 406.

THE CASE FOR MINIMAL INVASIVE UNICOMPARTMENTAL KNEE ARTHROPLASTY. A RETROSPECTIVE ANALYSIS OF 160 CASES.
J.N. Argenson, Y. Chevrol-Benkeddache, and J.M. Aubaniac
J Bone Joint Surg Br 2004 86-B: 406.

COMPUTER-NAVIGATION IN TOTAL-KNEE-REPLACEMENT WITH THE TC-PLUS(TM)SOLUTION KNEE-SYSTEM METHOD-EVALUATION-FIRST RESULTS
E.H. Hoffart
J Bone Joint Surg Br 2004 86-B: 407.

WHY AMC CERAMIC FOR KNEE COMPONENTS?
S. Leyen
J Bone Joint Surg Br 2004 86-B: 407.

INVESTIGATION OF THE WEAR BEHAVIOUR OF A CERAMIC KNEE CONCEPT WITH FLOATING MENISCAL BEARING
S. Leyen, J. Schwiesau, and R. Schmidt
J Bone Joint Surg Br 2004 86-B: 407.

IN VIVO DETERMINATION OF THREE DIMENSIONAL NORMAL KNEE MOTION DURING FIVE WEIGHT-BEARING ACTIVITIES
R. Komistek, D. Dennis, M. Mahfouz, W. Hoff, B. Haas, and D. Anderson
J Bone Joint Surg Br 2004 86-B: 407.

AN ASSESSMENT OF THE EFFECTIVENESS OF A PREOPERATIVE DENTAL VISIT
K. Moholkar and J. Corrigan
J Bone Joint Surg Br 2004 86-B: 407.

IS FILLING THE FEMORAL ENTRANCE HOLE IN TOTAL KNEE ARTHROPLASTY WORTH AN EFFORT?
K. Moholkar
J Bone Joint Surg Br 2004 86-B: 407-408.

URINARY CATHETERISATION AND TOTAL JOINT ARTHROPLASTY
A. Sajjad, K. Moholkar, and G. McCoy
J Bone Joint Surg Br 2004 86-B: 408.

A RANDOMIZED PROSPECTIVE STUDY OF SUBJECTS IMPLANTED WITH TWO DIFFERENT MOBILE BEARING TOTAL KNEE ARTHROPLASTY
E. Northcut, T. Sugita, K. Sato, B. Haas, and R. Komistek
J Bone Joint Surg Br 2004 86-B: 408.

IS THERE SUCH A THING AS LAMINAR FLOW?
T. Kochhar, D. Back, M.J. Wright, and N.B. Ker
J Bone Joint Surg Br 2004 86-B: 408.

LONG TERM PERFORMANCE OF THE SOUTER-STRATHCLYDE ELBOW ARTHROPLASTY
A.A. Malone, A. J. N. Taylor, and I. S. Fyfe
J Bone Joint Surg Br 2004 86-B: 408.

COMPARISON OF FIXED VS. MOBILE BEARING RANGE OF MOTION FOR JAPANESE PATIENTS HAVING EITHER A RESURFACED OR UNRESURFACED PATELLA
E. Northcut, M. Kobori, R. Komistek, B. Haas, S. Walker, and D. Macht
J Bone Joint Surg Br 2004 86-B: 408.

IN AN IN VITRO MODEL CAN NTX BE USED AS A MARKER OF WEAR PARTICULATE INDUCE OSTEOLYSIS INSTEAD OF THE ESTABLISHED RADIOLABELLED BONE MODEL.
S.M. Ong and G.J.S. Taylor
J Bone Joint Surg Br 2004 86-B: 409.

CEMENTLESS THA USING A CUSTOM-MADE BLASTED-SURFACE FEMORAL COMPONENT IN PATIENTS WITH SECONDARY OSTEOARTHRITIS OF THE HIP. FOUR- TO SEVEN-YEAR FOLLOW-UP STUDY.
T. Sakai, N. Sugano, K. Ohzono, S.B. Lee, T. Nishii, H. Miki, K. Haraguchi, and H. Yoshikawa
J Bone Joint Surg Br 2004 86-B: 409.

IN VIVO DETERMINATION CAM/POST ENGAGEMENT AND KINEMATICS OF THE FEMUR RELATIVE TO THE POLEYTHYLENE INSERT
D. Anderson, A. Lombardi, R. Komistek, E. Northcut, and D. Dennis
J Bone Joint Surg Br 2004 86-B: 409.

TOTAL KNEE ARTHROPLASTY AFTER DIFFERENT TYPE OF PROXIMAL TIBIAL VARUS OSTEOTOMY.
Y. Aoki, K. Yasuda, T. Majima, and A. Minami
J Bone Joint Surg Br 2004 86-B: 409.

THE EFFECTS OF OVER-TRACTION ON THE BLOOD FLOW OF THE SCIATIC NERVE BY PLACING THE HIP AND KNEE JOINTS IN VARIOUS POSITIONS
K. Koga
J Bone Joint Surg Br 2004 86-B: 409-410.

THE EFFECTS OF COLD THERAPY IN THE POSTOPERATIVE MANAGEMENT OF PAIN IN PATIENTS UNDERGOING TOTAL HIP ARTHROPLASTY
N. Saito, S. Kobayashi, M. Nawata, H. Horiuchi, and H. Ota
J Bone Joint Surg Br 2004 86-B: 410.

BIOLOGICAL FIXATION IN IMPLANT OF POROUS SURFACE USING OF YAG LASER
N. Omizu, H. Ito, H. Tanino, and T. Matsuno
J Bone Joint Surg Br 2004 86-B: 410.

BIODEGRADABLE HYBRID POROUS BIOMATERIALS FOR TISSUE ENGINEERING
T. Tateishi, G. Chen, and T. Ushida
J Bone Joint Surg Br 2004 86-B: 410.

INFLUENCE OF STABILITY ON RANGE OF MOTION AFTER CRUCIATE-RETAINING TKA
K. Yamakado, K. Kitaoka, H. Yamada, K Hashiba, A. Shimizu, R. Nakamura, and K. Tomita
J Bone Joint Surg Br 2004 86-B: 410.

MIGRATION RATES OF THE COLLARLESS POLISHED TAPERED (CPT) HIP REPLACEMENT
D.W. McGurty, M.C. Hynes, T. Greer, H.E. Ware, and Douglas W. McGurty
J Bone Joint Surg Br 2004 86-B: 410.

MANUAL VS COMPUTER MEASUREMENTS IN ASSESSING HIP MIGRATION
D.W. McGurty, M.C. Hynes, T. Greer, C.A. Wigderowitz, H.E. Ware, and Douglas W. McGurty
J Bone Joint Surg Br 2004 86-B: 410-411.

FEMORAL REVISION IN FAILED THA USING CEMENTLESS MODULAR STEMS
E. De Santis, G. Logroscino, G. Gasparini, F. Larosa, R. Sgrambiglia, and G. Magliocchetti
J Bone Joint Surg Br 2004 86-B: 411.

DOES THE SIZE OF A RADIOGRAPH MATTER?
D.W. McGurty, S. Prakash, C.A. Wigderowitz, R.J. Abboud, D.I. Rowley, and Douglas W. McGurty
J Bone Joint Surg Br 2004 86-B: 411.

IN VIVO DETERMINATION OF JOINT AND MUSCLE FORCES DURING GAIT AND DEEP FLEXION FROM FLUOROSCOPY
D. Komsitek, T. Kane, D. Dennis, and J. Ochoa
J Bone Joint Surg Br 2004 86-B: 411.

A PROSPECTIVE STUDY ON A NEW POROUS COATED AND HA STEM: 3 YRS F-U
E. De Santis, G. Logroscino, V. De Santis, L. Giannotta, F. Silvi, and S. Rivelli
J Bone Joint Surg Br 2004 86-B: 411.

MODEL-BASED ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS
B.L. Kaptein, E.R. Valstar, B.C. Stoel, P.M. Rozing, and J.H.C. Reiber
J Bone Joint Surg Br 2004 86-B: 411.

IMPACTION AUTOGRAFT ENHANCEMENT OF FEMORAL STEM FIXATION IN PRIMARY CEMENTLESS TOTAL HIP ARTHROPLASTY (THA)
P.A. Keblish
J Bone Joint Surg Br 2004 86-B: 411-412.

IN VIVO DETERMINATION OF HIP JOINT SEPARATION IN SUBJECTS HAVING VARIABLE BEARING SURFACES
R. Komistek, D. Dennis, L. Sedel, E. Northcut, and D. Anderson
J Bone Joint Surg Br 2004 86-B: 412.

WEAR OF RETRIEVED HIGH-DOSE CROSS-LINKED POLYETHYLENE SOCKETS IN LONG-TERM CLINICAL USE
H. Oonishi, H. Iwaki, and S. Masuda
J Bone Joint Surg Br 2004 86-B: 412.

CLINICAL RESULTS AFTER REVISION TOTAL KNEE ARTHROPLASTY
M. Nawata, S. Kobayashi, N. Saito, H. Horiuchi, H. Ohta, and K. Takaoka
J Bone Joint Surg Br 2004 86-B: 412.

A NEW NAVIGATION SYSTEM USED IN REVISION SURGERY OF THE KNEE
M. Sparmann
J Bone Joint Surg Br 2004 86-B: 412.

RELIABILITY AND MID-TERM RESULTS OF WAGNER SELF LOCKING PROSTHESES IN REVISION TOTAL HIP ARTHROPLASTIES.
Y.Y. Kim
J Bone Joint Surg Br 2004 86-B: 412-413.

TROCHANTERIC OSTEOTOMY FOR RECONSTRUCTION OF THE DEVELOPMENTAL DYSPLASIA OF THE HIP VS. OLD TUBERCULOUS HIP
Jae Yong Ahn
J Bone Joint Surg Br 2004 86-B: 413.

CEMENTLESS TOTAL HIP REPLACEMENT WITH CIRCUMFERENTIAL ACETABULAR MEDIAL WALL OSTEOTOMY IN DYSPLASTIC HIP
Myung-Chul Yoo
J Bone Joint Surg Br 2004 86-B: 413.

BONE REMODELLING AFTER INSERTION OF A CUSTOMISED FEMORAL STEM – CORRELATION BETWEEN IMPLANT VOLUME AND STRESS SHIELDING AFTER 2 YEARS, MEASURED WITH DEXA
A. Aamodt and P. Benum
J Bone Joint Surg Br 2004 86-B: 413.

DIGITAL TEMPLATING IN TOTAL HIP REPLACEMENT: A NEW GOLD STANDARD?
J. Bono
J Bone Joint Surg Br 2004 86-B: 413.

BISPHOSPHONATES ARE ASSOCIATED WITH REDUCED MICROMOTION OF KNEE PROSTHESES
R.G.H.H. Nelissen, E.H. Garling, M. de Haan, and E.R. Valstar
J Bone Joint Surg Br 2004 86-B: 413.

THE EFFECT OF BONE CEMENT VISCOSITY AND PERIPROSTHETIC CEMENT THICKNESS ON MIGRATION OF A POLISHED TAPERED HIP STEM AND UHMWP-CUP
R.G.H.H. Nelissen, E.H. Garling, and E.R. Valstar
J Bone Joint Surg Br 2004 86-B: 414.

A THREE-DIMENSIONAL CANAL FILL RATIO OF THE ANATOMICAL CEMENTLESS STEM IN JAPANESE PATIENTS WITH OSTEOARTHRITIS OF THE HIP JOINT
T. Sugimori
J Bone Joint Surg Br 2004 86-B: 414.

MICROMOTION AND KINEMATICS OF TOTAL KNEE PROSTHESES IN RELATION TO BEARING DESIGN: MOBILE VS. POSTERIOR STABILISED
E.H. Garling, R.G.H.H. Nelissen, and E.R. Valstar
J Bone Joint Surg Br 2004 86-B: 414.

POLYETHYLENE CROSSLINKING REDUCES WEAR IN TOTAL KNEE ARTHROPLASTY
D.D. D’Lima, J.C. Hermida, A. Bergula, P.C. Chen, and C.W. Colwell
J Bone Joint Surg Br 2004 86-B: 414.

MULTIPLE STAGE TREATMENT OF INFECTED JOINT ARTHROPLASTY
R.K. Sinha, C.B. Ma, J.E. Esway, and L.S. Crossett
J Bone Joint Surg Br 2004 86-B: 414.

FIVE TO TEN YEAR FOLLOWUP OF THE MULTILOCK HIP STEM
R.K. Sinha, J. Fenwick, J.D. Bobyn, and H.E. Rubash
J Bone Joint Surg Br 2004 86-B: 414-415.

FIBER-METAL STEM: EARLY EXPERIENCE WITH IMMEDIATE FULL WEIGHT-BEARING
Raj K. Sinha
J Bone Joint Surg Br 2004 86-B: 415.

COMPARATIVE STUDY OF HYDROXYAPATHITE COATED CUSTOM PROSTHESES : PRE-OPERATIVELY CUSTOMMADE ACCORDING TO CT SCAN DATA VERSUS INTRA-OPERATIVELY CUSTOMMADE HIP IMPLANTS.
M. Mulier
J Bone Joint Surg Br 2004 86-B: 415.

THE USE OF A TREVIRA TUBE FOR SOFT TISSUE REATTACHMENT AFTER WIDE EXCISION OF BONE TUMORS OF THE PROXIMAL HUMERUS
M.A. Rosa, G. Maccauro, G. Falcone, V De Santis, R. Ardito, and A. Sgambato
J Bone Joint Surg Br 2004 86-B: 415.

CELL REACTION AND BONE RESPONSE TO ZIRCONIA CERAMICS: EXPERIMENTAL STUDY
E. Pola, V. De Santis, G. Maccauro, C. Piconi, G. Gasparini, and E. De Santis
J Bone Joint Surg Br 2004 86-B: 415.

MASSIVE WEAR OF POLYETHYLENE LINERS INDUCING FRACTURE OF TITANIUM CUPS: BIOLOGICAL AND MECHANICAL ANALYSIS
G. Maccauro, L. Proietti, V. De Santis, E. Pola, and G. Gasparini
J Bone Joint Surg Br 2004 86-B: 415-416.

IN VIVO DETERMINATION POLYETHYLENE BEARING MOTION RELATIVE TO THE TIBIA AND THE FEMUR
R. Komistek, D. Kilgus, E. Northcut, B. Haas, and S. Walker
J Bone Joint Surg Br 2004 86-B: 416.

UNTITLED
M. Sparmann
J Bone Joint Surg Br 2004 86-B: 416.

THE COMPUTERISED DETERMINATION OF VALGUS/VARUS POSITION OF HIP PROSTHESIS
D.W. McGurty, P. Dilawari, C.A. Wigderowitz, R.J. Abboud, and D.I. Rowley
J Bone Joint Surg Br 2004 86-B: 416.

STRESS MEASURES ARE MORE SENSITIVE THAN KINEMATICS TO STIFFNESS IN A FINITE ELEMENT KNEE SIMULATOR
J. Rawlinson and D. Bartel
J Bone Joint Surg Br 2004 86-B: 416.

PYRAMID STEM
M. Spinelli and G. Bernicchi
J Bone Joint Surg Br 2004 86-B: 416.

THE USE OF COMPUTER ASSISTED NAVIGATION IN TKR: RESULTS OF AN INITIAL EXPERIENCE IN 35 PATIENTS
S.David Stulberg
J Bone Joint Surg Br 2004 86-B: 416-417.

THE TANTALUM MONOBLOCK ACETABULAR COMPONENT: RATIONALE AND THREE-YEAR FOLLOW-UP
S. David Stulberg
J Bone Joint Surg Br 2004 86-B: 417.

THE ROLE OF HYDROXYAPATITE IN THIRD-BODY POLYETHYLENE WEAR IN THA
V.J. Rasquinha, V. Mohan, B. Bevilacqua, J.A. Rodriguez, and C.S. Ranawat
J Bone Joint Surg Br 2004 86-B: 417.

UNTITLED
V.J. Rasquinha, A. Ranawat, B. Bevilacqua, J.A. Rodriguez, and C.S. Ranawat
J Bone Joint Surg Br 2004 86-B: 417.

THE PRESS-FIT CONDYLAR MODULAR TOTAL KNEE SYSTEM TWELVE-YEAR SURVIVORSHIP WITH A POSTERIOR CRUCIATE SUBSTITUTING DESIGN
V.J. Rasquinha, C.L. CervierI, B. Bevilacqua, J.A. Rodriguez, and C.S. Ranawat
J Bone Joint Surg Br 2004 86-B: 417.

LATERAL RELEASE AND PATELLO-FEMORAL TRACKING IN PS MOBILE BEARING KNEE
V.J. Rasquinha, B. Bevilacqua, J.A. Rodriguez, and C.S. Ranawat
J Bone Joint Surg Br 2004 86-B: 417-418.

AN IN-VITRO STUDY TO TEST IF DIFFERENT TKR’S DESIGNED FOR THE SAME INDICATIONS HAVE THE SAME KINEMATICS.
H. Haider and P.S. Walker
J Bone Joint Surg Br 2004 86-B: 418.

EVALUATION OF ACETABULAR DEFICIENCY IN REVISION THA: A NOVEL CLASSIFICATION AND RESULTS OF CEMENTLESS HEMISPHERICAL POROUS COATED CUP AND CANCELLOUS BONE GRAFT RECONSTRUCTION
V. Mathews, V.J. Rasquinha, D.M. Matusz, J.A. Rodriguez, and C.S. Ranawat
J Bone Joint Surg Br 2004 86-B: 418.

HEMISPHERICAL TITANIUM PLASMA SPRAY COATED ACETABULAR COMPONENTS IN NON-CEMENTED THA: 5 TO 9-YEAR FOLLOW-UP STUDY
V.S. Neginhal, V.J. Rasquinha, D. Holden, J.A. Rodriguez, and C.S. Ranawat
J Bone Joint Surg Br 2004 86-B: 418.

INFLUENCE OF MODULAR TIBIAL INSERT DESIGN ON BACKSIDE STRESS
B. Kirking, J. Green, and C. Parduhn
J Bone Joint Surg Br 2004 86-B: 418.

A RETRIEVAL ANALYSIS OF POLYETHYLENE DAMAGE IN TOTAL SHOULDER REPLACEMENTS
S. Li
J Bone Joint Surg Br 2004 86-B: 418-419.

EFFECT OF DIRECTLY MOLDING ACETABULAR CUPS ON THE CLINICAL AND HIP SIMULATOR WEAR RATES OF UHMWPE
S. L1, C.S. Ranawat, and B.D. Furman
J Bone Joint Surg Br 2004 86-B: 419.

MECHANICAL BEHAVIOR OF VITAMIN-E-CONTAINING UHMWPE
N. Tomita, Sakuramoto, I., A. Mori, N. Onmori, and E. Aoyama
J Bone Joint Surg Br 2004 86-B: 419.

SURVIVAL RATE AND WEAR RATE OF CHARNLEY TYPE TOTAL HIP ARTHROPLASTY WITH THREE SIZES OF ALUMINA CERAMIC HEAD COMPARED WITH ORTRON 90
K. Kawanabe, J. Tamura, and N. Nakamura
J Bone Joint Surg Br 2004 86-B: 419.

THE DEVELOPMENT OF NEW IMAGE MATCHING METHODS FOR MORE ACCURATE 3-D IN VIVO ANALYSIS OF TOTAL KNEE ARTHROPLASTY
T Kawano, H Miura, T Mawatari, T Morooka, H Higaki, S Matsuda, and Y Iwamoto
J Bone Joint Surg Br 2004 86-B: 419.

SURVIVORSHIP OF SEGMENTAL PROSTHETIC ARTHROPLASTY FOR LIMB SALVAGE FOLLOWING BONE SARCOMA RESECTIONS ABOUT THE KNEE
A.W. Yasko
J Bone Joint Surg Br 2004 86-B: 419-420.

OSSEOINTEGRATION OF HYDROXYAPATITE-COATED FEMORAL COMPONENTS
Y Nakashima, Y Noguchi, S Jingushi, T Shuto, T Yamamoto, E Suenaga, Y Kannekawa, and Y Iwamoto
J Bone Joint Surg Br 2004 86-B: 420.

A NEW SCAFFOLD FOR ARTICULAR CARTILAGE REGENERATION MADE OF FIBROIN SPONGE
H. Aoki, N. Tomita, Y. Morita, K. Ikeuchi, Y. Harada, S. Wakitani, Y. Tamada, and T. Suguro
J Bone Joint Surg Br 2004 86-B: 420.

CUSTOM-MADE FEMORAL COMPONENT INSERTED BY NON-REAMING TECHNIQUE: ACCURACY OF THE ROTATIONAL ANGLE
K. Kawate, T. Ohmura, N. Hiyoshi, T. Teranishi, K. Yokoi, K. Tamai, and T. Takakura
J Bone Joint Surg Br 2004 86-B: 420.

PROSTHETIC PATELLA GROOVE ORIENTATION IS OPPOSITE TO THE ANATOMIC ORIENTATION
M. Barink, S. van de Groes, N. Verdonschot, and M. de Waal Malefijt
J Bone Joint Surg Br 2004 86-B: 420.